Self-Regulating Process Temperature
  • Approximate Size 3/8"W x 1/8"H
  • Available in 5, 10, 15 Watts per Foot
  • Available in 120 and 208-277V models
  • Third-party certifications: FM
  • Process Temperature Maintenance to 230°F (110°C)
  • Maximum Continuous Exposure Temp, Power off, 275°F (135°C)
  • Circuit Lengths to 750 feet
  • T-Ratings - See data sheet
  • Min. Install Temp = -76°F (-60°C)
  • Min. Bend Radius 1-1/8"
  • For use on Metal Pipes & Tanks
  • Literature
    SRP Catalog Page
    DL Accessories Catalog Page
    U Series Accessories Catalog Page

Chromalox SRP self-regulating heating cable provides safe, reliable heat tracing for process maintenance applications to 230°F (110°C) or freeze protection of pipes / tank with high heat losses. Constructed of industrial grade 16 AWG buss wire with a tinned copper braid and optional overjacketing, SRP ensures operating integrity most hostile industrial environments.

Because SRP is self-regulating, overtemperature conditions are minimized. Chromalox U-Series Connection Kits reduce installation time.

  • Freeze Protection
  • Freeze Protection, High Exposure Temperature
  • Process Maintenance, Low Temperature
  • Process Maintenance, High Temperature

Features of SRP Cable

Max. Maintenance Temp. (°F) 225
Max. Exposure Temp. (°F) Power Off 275
Max. W/Ft. 15
Max. Circuit Length (Ft.) 55-750
Buss Wire Size 16
Voltages 120, 208-270
Hazardous Ratings Yes
Usable on Plastic Pipe No
Cut-to-Length in Field Yes
Field Splicable Yes
Can be Overlapped Yes
Output Varies with Temp. Yes
Varies Output Along Length Yes
Accessories D/UL
Monitor Wire Available Yes

SRP Corrosion Selection Guide

Moisture C, CT
Aqueous Solutions of Inorganic Compounds CT
Liquids Organic Chemicals Acids or Bases CT
Acids or Bases CT
C - Tin-Plated copper metallic braid for additional protection and ground path
CT - Fluoropolymer corrosion resistant overjacket over braid for hostile/corrosive environments

This is a recommendation guide. Chromalox cannot warrant any Electric Heat Trace against failure by sheath degradation if such failure is the result of operating conditions beyond the control of the heater manufacturer. It is the responsibility of the purchaser to make the ultimate choice of sheath material based on knowledge of the chemical composition of the corrosive solution, character of materials entering the solution, and controls which maintains the process.

Select Parameters
Output
Volts
Clear Parameters
Select a Part
Part # Description List Price  
387161 SRP 5-1C 120V 5W/FT 11.00 USD Buy Now
387217 SRP 5-2C 240V 5W/FT 11.75 USD Buy Now
387188 SRP 5-1CT 120V 5W/FT 14.25 USD Buy Now
387225 SRP 5-2CT 240V 5W/FT 14.50 USD Buy Now
387102 SRP 10-1C 120V 10W/FT 13.00 USD Buy Now
387170 SRP 10-2C 240V 10W/FT 13.75 USD Buy Now
387129 SRP 10-1CT 120V 10W/FT 15.75 USD Buy Now
387196 SRP 10-2CT 240V 10W/FT 16.00 USD Buy Now
387065 SRP 15-1C 120V 15W/FT 14.25 USD Buy Now
387110 SRP 15-2C 240V 15W/FT 14.75 USD Buy Now
387073 SRP 15-1CT 120V 15W/FT 17.00 USD Buy Now
387137 SRP 15-2CT 240V 15W/FT 17.75 USD Buy Now
Can't find what you're looking for?