Heat Trace Panels

Heat Trace Controls, Panels, Accessories / Heat Trace Panels

Overview

From state of the art Multiple Circuit Panels to best in class digital thermostats, Chromalox now offers a full line of industry leading Industrial Controls, Panel and Accessories to meet the most demanding Heat Trace applications. The ITLS/ITAS Panel Series is the flagship of the new fleet of products. The ITLS/ITAS Series provides 40 Amps of SSR Power switching in 6 – 72 circuits per system. It offers total process monitoring and management, either locally or remotely, including soft start and sensor mapping. The easy to program and navigate 10” touch screen computer is the brains behind the new system. Our DTS, the benchmark of digital thermostats, provides a single, 30 Amp point of control that also employs a soft start feature. Both of these new lines are suitable for Class I, Division 2 environments.

Scott Treser, Director of Controls and Panels, introduces model ITLS, a highly advanced heat trace control panel.

Find Your Model

Parameters:

RESET FORM

Select a Model to Spec:

 Model Description
FPAS Freeze Protection Ambient Sensing Series
FPASM Freeze Protection Ambient Sensing Monitor Series
FPLS Freeze Protection Line Sensing Monitor Series
FPLSM Freeze Protection Line Sensing Monitor Series
ITAS 6-36 Heat Tracing Ambient Sensing Control Panel
ITASC1D2 6-36 Ambient Sensing Heat Tracing Control Panel Class I, Div. 2, 6-72 Loops
ITASC1D2-EXT 6-36 Ambient Sensing Heat Tracing Control Panel Class I, Div. 2, 6-72 Loops
ITAS-EXT 6-36 Heat Tracing Extension Panel 6 to 36 Loops - Ambient Sensing
ITC1 & ITC2 Digital Heat Trace Controller 1 & 2 Circuit
ITLS 6-36 Heat Tracing Line Sensing Control Panel 6-36 Loops
ITLSC1D2 6-36 Line Sensing Heat Tracing Control Panel Class I, Div. 2, 6-72 Loops
ITLSC1D2-EXT 6-36 Line Sensing Heat Tracing Control Panel Class I, Div. 2, 6-72 Loops
ITLS-EXT 6-36 Heat Tracing Extention Panel 6 to 36 Loops - Line Sensing

13 Matching Items

Roll over results for more details

FPAS

  • Standard NEMA 4 Enclosures
  • NEMA 4X Stainless Steel Enclosure Option
  • Hand/Off/Auto Selector Switch
  • 15, 25, 30, and 40 Amp Single-pole and Double-pole 30 mA Ground Fault Thermal-Magnetic Circuit Breakers
  • See Catalog Page PDF for more information

FPASM

  • Standard NEMA 4 Enclosures
  • NEMA 4X Stainless Steel Enclosure Option
  • Hand/Off/Auto Selector Switch
  • 12, 18, 20, 30, and 42 Position Panelboards
  • See Catalog Page PDF for more information

FPLS

  • Standard NEMA 4 Enclosures
  • NEMA 4X Stainless Steel Enclosure Option
  • Hand/Off/Auto Selector Switch
  • 15, 25, 30, and 40 Amp Single-pole and Double-pole 30 mA Ground Fault Thermal-Magnetic Circuit Breakers
  • See Catalog Page PDF for more information

FPLSM

  • Standard NEMA 4 Enclosures
  • NEMA 4X Stainless Steel Enclosure Option
  • Hand/Off/Auto Selector Switch
  • 12, 18, 20, 30, and 42 Position Panelboards
  • See Catalog Page PDF for more information

ITAS 6-36

  • 10” VGA Touch Screen HMI
  • NEMA 4 Enclosure
  • SCR Control
  • Integral Circuit Panel with Circuit Breakers
  • 40 Amps/Loop @ 100 – 480 VAC
  • Optional Main Disconnect
  • Soft Start Feature
  • Full Communications
  • Enhanced Data Logging
  • Complete GFI Monitoring & Alarms
  • Load Monitoring & Alarms
  • Full Alarm Capabilities
  • Optional NEMA 4X
  • Optional Enclosure Heater
  • UL, cUL, CE, FM
  • Touch Screen Computer

ITASC1D2 6-36

  • Class I, Division 2 Hazardous Environments - Groups A,B,C,D
  • 12” VGA Touch Screen HMI
  • 40 Amps/Loop @ 100 – 480 VAC
  • SCR Control – PID, On/Off or Manual Control
  • 6 Loops to 72 Loops
  • NEMA 4 or NEMA 4X Enclosure
  • User Selectable Soft Start Feature
  • Optional Customizable I/O Mapping
  • Full Communications
  • Enhanced Data Logging
  • Full Alarm & Monitoring Capabilities on GFEP, Temperature, Sensor, Current Load & Communications
  • UL, cUL Listed
  • Optional CE Certification

ITASC1D2-EXT 6-36

  • Class I, Division 2 Hazardous Environments - Groups A,B,C,D
  • 12” VGA Touch Screen HMI
  • 40 Amps/Loop @ 100 – 480 VAC
  • SCR Control – PID, On/Off or Manual Control
  • 6 Loops to 72 Loops
  • NEMA 4 or NEMA 4X Enclosure
  • User Selectable Soft Start Feature
  • Optional Customizable I/O Mapping
  • Full Communications
  • Enhanced Data Logging
  • Full Alarm & Monitoring Capabilities on GFEP, Temperature, Sensor, Current Load & Communications
  • UL, cUL Listed
  • Optional CE Certification

ITAS-EXT 6-36

  • NEMA 4 Enclosure
  • SCR Control
  • Integral Circuit Panel with Circuit Breakers
  • 40 Amps/Loop @ 100 – 480 VAC
  • Optional Main Disconnect
  • Soft Start Feature
  • Soft Start Feature
  • Full Communications
  • Enhanced Data Logging
  • Complete GFI Monitoring & Alarms
  • Load Monitoring & Alarms
  • Full Alarm Capabilities
  • Optional NEMA 4X
  • Optional Enclosure Heater
  • UL, cUL, CE, FM

ITC1 & ITC2

  • 1 & 2 Circuit Models
  • 40 Amps per Circuit
  • SSR Control
  • 100 - 277 VAC, 50/60 Hz
  • Hazardous (Class I, Division 2) or Non Hazardous Areas
  • Soft Start Feature
  • Operating Temperature: -40°F to 104°F (-40°C to 40°C)
  • ModBus RTU/RS485 & RS422
  • 10” x 8” x 6” (26cm x 21cm x 15cm) NEMA 4X FG Wall Mount Enclosure
  • High Resolution Color TFT Display
  • LED Indication for Power, Load & Alarm per Circuit
  • Front Panel Capacitive Touch Switches
  • PID, On/Off or Manual Control Modes
  • One or Two Sensor Inputs / Circuit – Min, Max & Averaging
  • 2 Circuit Ambient Control from 1 RTD
  • Full Monitoring & Alarms (High / Low Temperature & Current, GFEP & Sensor Failure)
  • Programmable Duty Cycle On Sensor Failure
  • AC & DC Alarms
  • Password Protected Security Levels
  • UL, cUL for Ordinary & Class I, Div. 2 Hazardous Areas
  • CE

ITLS 6-36

  • 10” VGA Touch Screen HMI
  • Integral Circuit Panel with Circuit Breakers
  • Expandable to 72 Loops (with ITLS-EXT Extension Panels)
  • NEMA 4 Enclosure
  • SCR Control
  • 40 Amps/Loop @ 100 – 480 VAC
  • Optional Main Disconnect
  • Soft Start Feature
  • Full Communications
  • Enhanced Data Logging
  • Complete GFI Monitoring & Alarms
  • Load Monitoring & Alarms
  • Full Alarm Capabilities
  • Optional NEMA 4X
  • Optional Customizable I/O Mapping
  • Optional Enclosure Heater
  • Optional Enclosure Heater
  • cUL, UL
  • CE, FM Available
  • Touch Screen Computer

ITLSC1D2 6-36

  • Class I, Division 2 Hazardous Environments - Groups A,B,C,D
  • 12” VGA Touch Screen HMI
  • 40 Amps/Loop @ 100 – 480 VAC
  • SCR Control – PID, On/Off or Manual Control
  • 6 Loops to 72 Loops
  • NEMA 4 or NEMA 4X Enclosure
  • User Selectable Soft Start Feature
  • Optional Customizable I/O Mapping
  • Full Communications
  • Enhanced Data Logging
  • Full Alarm & Monitoring Capabilities on GFEP, Temperature, Sensor, Current Load & Communications
  • UL, cUL Listed
  • Optional CE Certification

ITLSC1D2-EXT 6-36

  • Class I, Division 2 Hazardous Environments - Groups A,B,C,D
  • 12” VGA Touch Screen HMI
  • 40 Amps/Loop @ 100 – 480 VAC
  • SCR Control – PID, On/Off or Manual Control
  • 6 Loops to 72 Loops
  • NEMA 4 or NEMA 4X Enclosure
  • User Selectable Soft Start Feature
  • Optional Customizable I/O Mapping
  • Full Communications
  • Enhanced Data Logging
  • Full Alarm & Monitoring Capabilities on GFEP, Temperature, Sensor, Current Load & Communications
  • UL, cUL Listed
  • Optional CE Certification

ITLS-EXT 6-36

  • 10” VGA Touch Screen HMI
  • Enhanced Data Logging
  • NEMA 4 Enclosure
  • SCR Control
  • Integral Circuit Panel with Circuit Breakers
  • 40 Amps/Loop @ 100 – 480 VAC
  • Optional Main Disconnect
  • Soft Start Feature
  • Full Communications
  • Complete GFI Monitoring & Alarms
  • Load Monitoring & Alarms
  • Full Alarm Capabilities
  • Optional NEMA 4X
  • Optional Customizable I/O Mapping
  • Optional Enclosure Heater
  • UL, cUL, CE, FM
  • Applicable Feature When Paired with Matching intelliTRACE ITLS Control Panel

Can't find the Heat Trace Panel you're looking for? Request a Quote