Showing 121-130 of 881 results

Immersion Heaters for Flange Water Applications [Catalog Page]

As with our screw plug immersion heaters, the term “ WATER” can refer to very different qualities of fluid (PH / dissolved mineral materials / additive fluids / drinking use / etc...) which require suitably designed heaters. We consequentially propose standard ranges with carbon steel or stainless steel flanges, stainless steel or incoloy sheathed elements, brazed or welded. Watts density of 9 to 10 W/sq.cm suit to the majority of clean water, other ranges with reduced Watt density (4 or 5 W/cm2) are also available.

Media Library

International (English)
PDF - Catalog Page

Circulation Heaters [Design Guide]

Specification for Circulation Heaters. Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation of the application. After determining the heat requirement for a specific heat application, the proper selection of the flange and vessel material, heating element sheath material, and correct watt density is critical to achieve long heater life. The ultimate selection of equipment is determined by the knowledge of the process and engineering acumen of the designer or plant engineer. Consult the Technical section of this catalog for circulation heater calculations and guidelines.

Media Library

International (English)
PDF - Design Guide

Fan Heaters for Hazardous Areas [Technical Overview]

Accessories Specifications for Fan Heaters for Hazardous Areas - Fan heaters for hazardous areas - Large range from 3 to 30kW. Heat is created by an immersion heater in a “Polypropylene glycol / Air” heat exchanger which in turn is passed through a liquid to air heat exchanger. Highly compact design with no risk of hot spots. Built in overpressure protection device and manual reset thermal cut out.

Media Library

International (English)
PDF - Catalog Page

Convection Heaters for Hazardous Applications [Technical Overview]

Accessories Specifications for Convection Heaters for Hazardous Applications - ATEX type "d" certified heaters without casing, ATEX certified convection heaters, Ex "e" ATEX certified convector heaters, EEx "d" ATEX Wall mounting convection heaters, Recommended Control for ATEX-G Heaters.

Media Library

International (English)
PDF - Catalog Page

Immersion Heaters for Process Applications [Catalog Page]

Chromalox offers the global solution. Certifications and Standards, Codes and standards for pressure vessels and heaters, Design rules, Petrochemicals, Chemicals, Engineering contractors, Pharmaceutical & Cosmetics, Air separation, Power generation & compression, Sewage & water treatment, Transport, and Food & Beverage.

Media Library

International (English)
PDF - Catalog Page

Immersion Heaters for Screw Plug Oil Applications [Catalog Page]

Immersion heaters are the most efficient method of heating an almost limitless range of liquids. They usually consist of sheathed heating elements bent into a hairpin shape and mounted onto a screw plug or onto a flange. They are fitted to a vessel or tank using a boss, back nut or mating flange.

Media Library

International (English)
PDF - Catalog Page

Tubular Heaters [Design Guide]

Specification for Tubular Heaters. Tubular heating elements perform exceptional heat transfer by conduction, convection or radiation to heat liquids, air, gases and surfaces. In most heater assemblies, tubular element design configurations vary — round, triangular, flat press and formed. Bends are made to customer requirements Custom built from 0.200" to 0.475" diameters, a multitude of sheath materials with sheath temperature capabilities up to 1600°F, watt densities to fit many applications and up to 600 volts. Available with over 20 optional terminations and many stocked accessories.

Media Library

International (English)
PDF - Design Guide

FSRM Modular Hopper Heater [Installation Manual]

Installation instructions for Type FSRM Modular Hopper Heater. High Temperature Modular Hopper Heaters can be made to order to your hopper specifications. Low watt densities ensure long life while providing operating temperatures of 250°F (120°C) to 350°F (175°C) or higher. These are commonly used in Electrostatic Precipitators and Fabric Filter Dust Collecting Hoppers.

Media Library

International (English)
PDF - Installation Manual

NS & NSL 3/4" Wide High Temperature Strip Heaters [Technical Overview]

Specification for NS and NSL strip heaters. Chromalox High Density Strip Heaters are constructed using our own proprietary refractory cement and are highly compacted for excellent heat transfer. These are primarily used for convection type air heating and clamp on conductive heating. The strip heaters are available in a wide variety of widths and lengths. There are many different options for sheath material, terminations, mounting and electrical ratings. Depending upon sheath materials the compacted strip can obtain temperatures up to 1500°F (815°C). These heaters are highly suited for many industrial and commercial applications.

Media Library

International (English)
PDF - Catalog Page

LEGACY - RCH-F Flat Face Ceramic Radiant Heater [Technical Overview]

Specification for RCH-F flat face ceramic radiant heater. Secure Electrical Connections are made by welding resistance wire to lead wire. Other designs simply twist the wires for a less reliable connection. Higher Temperature Capability is possible with 6" long heavy duty, flexible lead wires.

Media Library

International (English)
PDF - Catalog Page