Showing 1291-1300 of 1357 results

MTI & EMTI Solution Water Applications [Technical Overview]

Specifications for MTI & EMTI Solution Water Applications. Screw plug immersion heaters consist of tubular elements in a threaded hex plug. Some models are provided with a thermowell for the temperature control sensor and a variety of electrical enclosures for electrical connections. They screw directly through threaded openings in tank walls to heat liquids, viscous fluids, forced air, and gases by direct contact. A patented 360º rotatable housing is available on most models to facilitate easy conduit connections.

Media Library

International (English)
PDF - Catalog Page

RBF Heat Trace or Pipe Sensor [Technical Overview]

Specification for RBF heat trace or pipe sensor. For measuring the surface temperature of process piping that is carrying products whose temperatures must be controlled to prevent freeze-up, or to maintain a viscosity level so that the inner medium will flow. The RTD Sensor Element is made up with a 316SS sheath, and with a stainless steel mounting pad. Cold legs are available in customer specified lengths to accommodate pipe insulation thickness.

Media Library

International (English)
PDF - Catalog Page

1604mA 1/16 DIN Temperature Controller [Technical Overview]

Specification for 1604mA 1/16 DIN temperature controller. The 1604mA controller is an fully featured dual 4-digit display 1/16 DIN with the control features of a sophisticated Auto-tuning PID controller. All 1604mA controllers are equipped with a flexible 4-20 or 0-20mA output and 2 Relay outputs. The analog output can be programmed as a control output or a retransmit output for either the process or set point. The relays can be programmed as either Control or Alarm Outputs.

Media Library

International (English)
PDF - Catalog Page

Expansion Tanks System Options [Technical Overview]

Specification for expansion tanks. An expansion tank is an essential component to all heat transfer systems. Heat transfer fluids expand with an increase in temperature. Expansion tanks allow for and contain the increase in volume due to temperature. In addition, cold expansion tanks provide a “seal” on the system reducing oxidation of the fluid. They also add to the net positive suction head (NPSH) on the inlet to the pump.

Media Library

International (English)
PDF - Catalog Page

CONT Definite Purpose Magnetic Contactor [Technical Overview]

Specification for CONT definite purpose magnetic contactor. The CONT contactors are used for heating loads where the voltage, number of phases or ampere draw exceeds the rating of themostat. Some models are available from stock with and without enclosures.

Media Library

International (English)
PDF - Catalog Page

Control Accessories [Technical Overview]

Specification for control accessories for connectors, fittings, and adapters.

Media Library

International (English)
PDF - Catalog Page

1020 & 1030 Temperature Controllers [Installation Manual]

Installation instructions for 1020 & 1030 Process and Over-Temperature Controllers. The 1020 DIN rail temperature & process controller is the latest addition to the Chromalox 20 Series controller line. This new controller is cost effective, easy to install, extremely fast to configure and comes equipped with the most desirable standard or optional advanced control features. The 1030 DIN Rail Over Temperature Controller is an ideal complement in both design and aesthetics to its cousin, the Chromalox 1020 Temperature/Process Controller. This fail-safe protection device may be used to shut down a process when the preset parameter threshold is realized. The controller cannot be reset until the process has returned to an acceptable parameter condition.

Media Library

International (English)
PDF - Installation Manual

MWS Series Water & Water / Glycol System [Installation Manual]

Installation Instructions for MWS Series water & water/glycol system. Chromalox MWS - Mid-Size Water/Glycol System - is engineered to operate to 300˚F (150˚C) with either water or water/glycol fluids. Its electric heating core assures responsive and precise temperature control in a space saving package. The system is suitable for a large range of heating needs with a compact design. The MWS operates in a closed loop system using a cold expansion tank (optional).

Media Library

International (English)
PDF - Installation Manual

LEGACY - MiniMax™ 1 Single Phase SCR Power Pak [Technical Overview]

LEGACY - Specification for MiniMax™ 1 single phase SCR power pak. The MiniMax™ Series is specifically designed for the OEM market. The plug-in options, flexible I/O power wiring, space saving footprint, I2 t fusing and universal approvals make it an excellent candidate for your product.

Media Library

International (English)
PDF - Catalog Page

Wastewater Treatment Brochure

Heating and Control Solutions For the Wastewater Treatment Industry

Media Library

International (English)
PDF - Catalog Page