Convection Air Heaters - CSA Certification [Certification]
CSA Group Certification for Heaters-Air - stationary type for hazardous locations.
Media Library
LEGACY - MB-2 Two-Piece Mica Insulated Band Heater [Technical Overview]
LEGACY - Specification for MB-2 two-piece mica insulated band heater. Chromalox type MB-2 commercial heaters offer thin, efficient commercial heating. Heat from the precisely wound resistance element is quickly transferred to the working surface for fast heat-up and response. Mica band heaters provide excellent dielectric strength and heat transfer capability for long heater life. The mica core is encased in a continuous corrosion resistant sheath and formed. All full mica band heaters are designed with closed ends to protect against contamination. Maximum sheath temperature is 800°F.
Media Library
S-RAD Single Element Radiant Heaters [Technical Overview]
Specification for S-RAD Single Element Radiant Heater. Enclosed Chromalox Alloy-Sheath Tubular Heating Element is completely isolated and supported on secondary insulation for improved electrical safety. Designed for long life, the element is more resistant to hard blows than quartz lamp or tube and open coil types.
Media Library
Circulation Heaters [Overview]
Overview for Chromalox Circulation Heaters. Circulation heaters are packaged units designed to heat a flowing medium using in-line or side-arm piping configurations. Complete units consist of built-in heating elements, a heating chamber, thermostat and/or sensors (stock units), insulation, insulation jacket, mounting brackets and inlet and outlet connections.
Media Library
AEPS Explosion Proof Strip Heater [Installation Manual]
Installation instructions for Type AEPS Explosion Proof Strip Heaters. Chromalox Type AEPS explosion proof electric strip heaters are ideal for the control of moisture in mechanical conveyor lines, vibrating feeders or other automatic material handling equipment. This heavy-duty strip heater safely prevents freezing of the mate rials transported.
Media Library
Flange Immersion Heaters - Water Safe [Technical Overview]
Accessories Specifications for Flange Immersion Heaters - Water Safe - Light flange OEM immersion heaters, Thermostat for OEM Immersion Heaters, Single pole rod thermostat, Single pole miniature rod thermostat, Rod single phase thermostat and cutout, Clampable flange immersion heaters, Flanged Immersion heaters, Flanged Immersion heaters 150 Ib ANSI, Immersion heaters with withdrawable elements.
Media Library
Cast Plate Heaters [Technical Overview]
Accessories Specifications for Cast Plate Heaters - Cast plate heaters, Sheathed elements cast into aluminium, aluminium bronze, cupronickel or cast iron. Cast heaters are designed and manufactured specifically for each application. They are extremely robust, provide excellent heat diffusion and can be fitted with integral cooling systems.
Media Library
Legacy - Flanged Immersion Heaters for Water [Technical Overview]
Specification for flanged immersion heaters - water. Flanged immersion heaters are one of the most widely used methods for commercial heating of gases and liquids, such as water, oil, heat transfer fluid, and corrosive solutions. Designed for use in tanks and pressurized vessels, they are easy to install and maintain to provide heat for many processes. The direct immersion method is energy efficient and easily monitored and controlled. Flanged immersion heaters are used in a wide variety of applications, such as hot water storage tanks, warming equipment, preheating oil, food processing equipment, cleaning and rinsing tanks, heat transfer systems, process air equipment, boiler equipment, and freeze protection.
Media Library
Legacy - IEC-EC Flanged Immersion Heaters - Oil [Technical Overview]
Specification for flanged immersion heaters - oil. Flanged immersion heaters are one of the most widely used methods for commercial heating of gases and liquids, such as water, oil, heat transfer fluid, and corrosive solutions. Designed for use in tanks and pressurized vessels, they are easy to install and maintain to provide heat for many processes. The direct immersion method is energy efficient and easily monitored and controlled. Flanged immersion heaters are used in a wide variety of applications, such as hot water storage tanks, warming equipment, preheating oil, food processing equipment, cleaning and rinsing tanks, heat transfer systems, process air equipment, boiler equipment, and freeze protection.
Media Library
LEGACY - MB-1 One-Piece Mica Insulated Band Heater [Technical Overview]
LEGACY - Specification for MB-1 one-piece mica insulated band heater. Chromalox type MB-1 commercial heaters offer thin, efficient commercial heating. Heat from the precisely wound resistance element is quickly transferred to the working surface for fast heat-up and response. Mica band heaters provide excellent dielectric strength and heat transfer capability for long heater life. The mica core is encased in a continuous corrosion resistant sheath and formed. All full mica band heaters are designed with closed ends to protect against contamination. Maximum sheath temperature is 800°F.