SRP Self-Regulating Process Temperatures [Technical Overview]
Specification for SRP Self-Regulating Process Temperatures. Chromalox SRP self-regulating heating cable provides safe, reliable heat tracing for process maintenance applications to 230°F (110°C) or freeze protection of pipes/tank with high heat losses. Constructed of industrial grade 16 AWG buss wire with a tinned copper braid and overjacketing, SRP ensures operating integrity most hostile industrial environments.
Media Library
AS-BM Ambient Heat Trace Sensor [Technical Overview]
Specification for AS-BM Ambient Heat Trace Sensor. The Chromalox AS-BM sensor is used for measuring the ambient air temperature. The RTD sensor element is made up with a Copper sheath and can be installed directly to a controller or junction box using the 1/2” NPT conduit fitting.
Media Library
SRF-RG Roof & Gutter Heat Trace System [Technical Overview]
SRF-RG heating cable by Chromalox provides reliable freeze protection of roofs and gutters. Because SRF-RG is self-regulating, it automatically adjusts to the appropriate heat output as ambient conditions change, making it both energy efficient and cost effective. The protective waterproof outer jacket is suitable for wet applications in downspouts and roof drains.
Media Library
Temperature & Process Controller Selection Guide [Technical Overview]
Overview of Chromalox Temperature and Process Controller Selection. Chromalox provides a wide array of Temperature Sensors for Industrial and Commercial applications to assure precise and accurate temperature control of critical processes. Temperature Sensors are used to measure temperature in countless different industrial processes, laboratory and medical instruments and commercial applications. We specialize in providing custom manufactured Thermocouples and RTD's specifically designed to meet individual customer requirements, as well as providing a large stock inventory of thermocouples for immediate delivery. In addition, we stock a wide range of temperature sensing accessories.
Media Library
REACH Statement of Compliance - Directive 1907/2006/EC
Directive 1907/2006/EC is the European Union regulation concerning the Registration, Evaluation, Authorization and Restriction of Chemicals (REACH). This directive came into regulatory force on 1 June 2007 in the European Union and replaces a number of European Directives and Regulations with a single system. The REACH directive establishes provisions on chemicals and their use. Not only does this directive cover “stand alone” chemicals, but the directive also encompasses chemicals within mixtures and substances, as well as preparations of chemicals within the scope of Article 3 found in the directive. These provisions apply to the manufacture of substances, placing substances on the market, or use of such substances. “Use of substance” is interpreted as using a substance on their own, in process preparations, or in articles.
Media Library
HL Hazardous Location Connection Kits [Technical Overview]
Specification for HL hazardous location connection kits. The HL Series Connection System for Chromalox heating cable products is specifically designed to comply with the requirements of Division 1 hazardous areas.
Media Library
Process Air Heaters [Technical Overview]
Specification for Process Air Heaters . Heat processing applications vary widely from industry to industry. Curing, drying, heat treating, comfort heating, sterilizing and bonding represent just a few of the many uses for electrically heated air. Applications vary in temperature from super cool cryogenic to high temperatures up to 1200°F. Chromalox electric heaters can also be designed to heat special atmospheres such as argon or nitrogen. Special materials and custom designs are available for marine applications, power plants or hazardous applications.
Media Library
S-RAD Single Element Radiant Heaters [Technical Overview]
Specification for S-RAD Single Element Radiant Heater. Enclosed Chromalox Alloy-Sheath Tubular Heating Element is completely isolated and supported on secondary insulation for improved electrical safety. Designed for long life, the element is more resistant to hard blows than quartz lamp or tube and open coil types.
Media Library
LEGACY - MB-2 Two-Piece Mica Insulated Band Heater [Technical Overview]
LEGACY - Specification for MB-2 two-piece mica insulated band heater. Chromalox type MB-2 commercial heaters offer thin, efficient commercial heating. Heat from the precisely wound resistance element is quickly transferred to the working surface for fast heat-up and response. Mica band heaters provide excellent dielectric strength and heat transfer capability for long heater life. The mica core is encased in a continuous corrosion resistant sheath and formed. All full mica band heaters are designed with closed ends to protect against contamination. Maximum sheath temperature is 800°F.
Media Library
Thermocouple Sensors (Special Purpose) [Technical Overview]
Specification for Thermocouple Sensors. The Sensors shown on this page represent some models designed for specific applications. They include a 6" by 1/8" diameter J thermocouple with 10' Fiberglass® leads, and a type K thermocouple with identical physical characteristics.