ARMTO-2 & AREMTO-3 Heavy Weight Oil Applications [Technical Overview]
Specification for ARMTO-2 and AREMTO-3 heavy weight oil applications. Screw plug Immersion heaters consisting of hairpin bent tubular elements brazed or welded into a screw plug, integral thermostat, and provided with terminal enclosures for electrical connections. Chromalox MTO industrial heaters use direct immersion for energy efficiency, and are well suited for light, medium, and heavy weight oil applications.
Media Library
ARMTS Process Water Applications [Technical Overview]
Specification for ARMTS process water applications. Screw plug immersion heaters consisting of hairpin bent stainless steel tubular elements brazed or welded into a screw plug, integral thermostat, and provided with terminal enclosures for electrical connections. Chromalox ARMTS industrial heaters use direct immersion for energy efficiency and are well suited for process water and corrosive solution applications.
Media Library
AREMTI-3-MC Mildly Corrosive Solution Applications [Technical Overview]
Specification for AREMTI-3-MC. Screw Plug Immersion heaters consisting of hairpin bent incoloy tubular elements brazed or welded into a screw plug, integral thermostat, and provided with terminal enclosures for electrical connections. Chromalox ARMTI industrial heaters use direct immersion for energy efficiency and are well suited for solution water and corrosive solution applications.
Media Library
IntelliTrace™ RSP Remote Sensor Panel [Technical Overview]
Specification for IntelliTrace™ RSP remote sensor panel. The Chromalox RSP remote sensor panel greatly reduces installation costs as it facilitates the monitoring of 1 - 252 heat trace temperature sensor inputs within a single enclosure. The RSP is a completely integrated package and it works seamlessly with the Chromalox IntelliTrace ITLS/ITAS heat trace control panels in either ordinary or hazardous areas.
Media Library
HWM Hot Water Maintenance Heat Trace Cable [Technical Overview]
Specification for HWM hot water maintenance heat trace cable. The HWM hot water temperature maintenance system utilizes self-regulating heat trace technology. The system, consisting of the self-regulating cable, connection kits and specialized electronic controls, provides commercial buildings with immediate hot water availability without expensive recirculation systems. It provides a simple, yet energy efficient approach by providing heat at the point where heat loss occurs. Due to the parallel construction of the self-regulating cable, it can be cut to any length, spliced, tee-branched and terminated on site. With this product, energy savings may be derived from multiple sources, such as lower supply line heat loss, eliminated return line heat loss, no pump operating costs and no supply water overheating costs.
Media Library
Legacy - GSL3, GTL3, GDSL3 & GDTL3 L-Shaped Metal Tube Heaters [Technical Overview]
Specification for GSL3, GTL3, GDSL3 and GDTL3 L-shaped metal tube heaters. Chromalox Over-the-Side Immersion Heaters are designed for installing in the top of a tank with the heated portion directly immersed along the side or at the bottom. This provides easy removal of the heater and ample working space inside the tank. Our commercial heaters are available with heating elements made of Copper, Steel, Stainless Steel, Cast Iron, INCOLOY®, Titanium, Fluoropolymer coated, and Quartz. A wide selection of kW ratings, shapes and mounting methods are available to suit many different types of applications.
Media Library
LA-03, 10, 50 Ambient Sensing Heat Trace RTD [Technical Overview]
Specification for LA-03, 10, 50 ambient sensing heat trace RTD. The Chromalox LA-03, 10, 50 are used for measuring the ambient air temperature. The RTD sensor is made up with a 316 SS Sheath and can be installed directly to a controller or junction box using the optional 1/2" conduit fitting. These RTDs come in standard lengths of 3ft, 10ft and 50ft.
Media Library
TEH Tubular Enclosure & Switchgear Heaters [Technical Overview]
Specification for TEH Tubular Enclosure & Switchgear Heaters. TEH Tubular Enclosure Heaters and General Purpose Air Heaters are used for freeze protection and condensate protection in electrical enclosures and switchgear. They can also be installed in equipment to keep mechanical components functioning in applications such as valve enclosures and line metering.
Media Library
TMO Oil Heaters [Technical Overview]
Specifications for TMO Oil Heaters. A catalog page summarizing the TMO Oil Heaters including specifications and ordering information. For International Markets - Chromalox offers a dedicated flanged immersion product offering with features needed for particular regions. Standard models include TBR, HTBR, FO, FA, FR, TRHGB, FPF, FPR, and EXF heaters.
Media Library
URPT 3/8" Dia. Heart Cross-Section [Technical Overview]
Specifications for URPT 3/8" Dia. Heart Cross-Section. Type 8 Terminals — Standard with threaded clip to facilitate wiring. Specification for TI 3/8" Dia. Triangular or Heart Shaped cross-section is recommended for certain heavy duty applications. It has added structural strength, achieved through die pressing, which resists deformation or sagging when installed in the flow of high velocity air or thick oils and compounds, or in high surface temperature air heating. Bends are made to customer requirements: custom built from 0.375" to 0.500" diameters, a multitude of sheath materials with sheath temperature capabilities up to 1600°F, and watt densities to fit many applications up to 600 volts. Heart Cross-Section. Type 3 Terminals — Heliarc-welded to the cold pin.