Showing 521-530 of 1357 results

Food and Beverage Chocolate and Sauce Facilities Brochure

Showcasing the Chromalox solutions used across the food and beverage processes to manufacture chocolate and sauces

Media Library

International (English)
PDF - Brochure

Comfort Heaters Selection Guidelines [Technical Overview]

Specification and Selection Guidelines for Comfort Heaters. Radiant Infrared Comfort Heaters can help many unique heating situations. Heats People Without Heating Air — Infrared travels through space and is absorbed by people and objects in its path. The air does not absorb infrared energy. With convection heating the air itself is warmed and circulated, however, warm air always rises to the highest point of a building. With Infrared comfort heating, the warmth is directed and concentrated at the floor and people level where it is really needed.

Media Library

International (English)
PDF - Catalog Page

Heat Trace Control & Panel Selection Guide [Technical Overview]

Specification for Heat Trace Control & Panel Selection Guide. The DTS-HAZ is a single circuit controller which switches 30 Amps at 100-277 Vac in Class I, Division 2 areas. It employs SSR on/off control, soft start feature, programmable parameter values, AC or DC alarm and large LED display. It comes complete with a standard pipe stand or optional wall mount as well as an RTD sensor. All of this is housed in a 6" x 6" enclosure, which facilitates all wiring needs.

Media Library

International (English)
PDF - Catalog Page

Packaged Heat Transfer Systems [Design Guide]

Specification for Packaged Heat Transfer Systems. Chromalox Heat Transfer Systems are used in process heating applications requiring closely controlled process temperatures. Systems are furnished complete with heaters, controls, pumps, valves and necessary plumbing.

Media Library

International (English)
PDF - Design Guide

Skin-Effect Heat Trace System [PDS]

PDS for Skin-Effect Heat Trace System. Chromalox skin-effect trace heating is ideal for the freeze protection, temperature maintenance, and heat-up of materials transported by long-distance pipelines (up to 15 miles/25 kilometers). Pipes can be above or below ground, submerged, and across all types of terrains.

Media Library

International (English)
PDF

Freeze & Snow Protection [Technical Overview]

Accessories Specifications for Freeze and Snow Protection - Electrical Heat Tracing for buildings, Self-regulating cables for roofs, Roof cable clips, Gutter downspout hanger kits, Roof and gutter cable splice kit, Self-regulating cables for cold pipes,Self regulating cable for hot pipes, Fixing adhesive tape, Contact adhesive tape, Splice and T Kit, In line IP67 connection, Through bulkhead kit, Cable Polymer Stripper, End kit for connection in boxes, PVC IP55 connection box, Polyester connection box IP67, IP55 Connection box with freezing detection, Glands with specific washer, Silicon end seal kit, Complete kit for 1 line of trace heating, Accessories for cables in building application, Recommended controls for association with building heat tracing, Control for roofs trace heating, Control for pipes trace heating, Cables for buildings.

Media Library

International (English)
PDF - Catalog Page

IECEx ITS 15.0018X - IEC Certification Scheme for Explosive Atmospheres [Certification]

The Chromalox CCX Cast Block Heater is based on the CFP family of heaters, certified in certificate numbers IECEx ITS 03.0007X for the CFP8 and IECEx ITS 03.0008 for CFP JB (Junction Box) sensor enclosure. The terminal housings are provided by the CFP8 model which is drilled to accept metal sheathed heating element. These elements pass through flameproof glands into the base. This version incorporates an Aluminium block which is cast around the heating elements. The process medium flows through the cast block inlet and outlet connections and the process medium is in turn heated. A stand off is provided to limit the temperatures in the CFP enclosure. If the stand off is insulated then this thickness is added to the overall stand off dimension and not incorporated.

Media Library

International (English)
PDF

OCE Open Coil Heaters [Technical Overview]

Overview of Chromalox OCE Open Coil Element Ordering. The OCE type (open coil element) electric heating element(s) supplied herein is ruggedly constructed and designed for long life. When properly installed, operated and maintained, it should give dependable, trouble free service.

Media Library

International (English)
PDF - Catalog Page

Legacy - Chromalox CX224 Software [Installation Manual]

Installation instructions for Chromalox CX224 Software - Setup Tutorial. The CX224 consists of a 12-Channel Temperature Monitor and ChromaSoft™ CX224 Software. It is the next generation in temperature monitoring equipment from Chromalox designed to meet the needs of electric machinery protection. The 12-channel scanning capability, standard RS485/RS232 interface and Windows-compatible software utility for system configuration and data logging provide overtemperature and under temperature protection and critical feedback to safeguard expensive machinery.

Media Library

International (English)
PDF - Installation Manual

Legacy - CAF-12 & CCAS-12 Architectural Convection Heaters [Installation Manual]

Installation instructions for Architectural Convection Heaters Type CAF-12 and CCAS-12. This document explains the correct procedure for the installation and safe operation of all models of Draft Barrier and Pedestal Mounted Heaters. Draft Barriers and Pedestal Mounted Heaters are intended for wall, sill or floor mounting. The heaters are designed so that they may be used as an individual cabinet convector, in a wall-to-wall configuration or as an end-to-end continuous perimeter room heating system.

Media Library

International (English)
PDF - Installation Manual