Chromalox HSRM self-regulating heating cable provides safe, reliable heat tracing for freeze protection of pipes, valves, tanks and similar applications. Constructed of industrial grade 16 AWG buss wire with a tinned copper braid and fluoropolymer overjacket, HSRM ensures operating integrity in Div. 1 hazardous environments. HSRM heating cable has a maximum maintenance temperature rating of 302°F (150°C) and a maximum exposure temperature of 420°F (215°C).
Note: Due to the nature of Division 1 hazardous location applications consultation with a factory representative is required.
WARNING — A ground fault protection device
is required by NEC to minimize the danger of
fire if the heating cable is damaged or improperly
installed. A minimum trip level of 30mA is
recommended to minimize nuisance tripping.
- Energy efficient, self-regulating HSRM uses
less energy when less heat is required.
- Easy to install, HSRM can be cut to any
length (up to max circuit length) in the field.
- HSRM features lower installed cost than
steam tracing, less maintenance expense
and less down time.
- HSRM can be overlapped without burnout,
which simplifies heat tracing of in-line process
equipment such as valves, elbows and
pumps.
- Chromalox HL Connection Kits reduce installation
time.
Approvals
FM Approved:
- Class I, Division 1, Groups B, C, D
- Class II, Division 1, Groups E, F, G
- Class III, Division 1
- 5 and 8 Watt rated T3C Temperature Class
- 10 Watt rated T3A Temperature Class
- 15 and 20 Watt rated T2C Temperature Class
CSA Approved:
- Class I, Division 1, Groups B, C, D
- Class II, Division 1, Groups E, F, G
- 5 and 8 Watt rated T3C Temperature Class
- 10 Watt rated T3A Temperature Class
- 15 and 20 Watt rated T2C Temperature Class